CodeSec AA45R repeater panel for monitoring and controlling an AA504 addressable fire panel from a second location: all panel functions, 120 × 64 graphic LCD, 16 zone LEDs, RS485.
Resideo R200C2-A measures carbon dioxide (CO2, NDIR sensor), temperature and humidity; green/amber/red indicator and 75 dB voice alarm, 10-year service life.
Detnov MAD-450-IW addressable red manual call point with built-in isolator for outdoor use: IP67, resettable element with a break-glass feel, LED status indicator, key included.
Detnov MAD-411-I addressable relay module: 1 relay (C/NO/NC, 1 A 30 V DC), built-in isolator, loop powered, DIN rail or BOX-ONE box; EN 54-18 / EN 54-17.
Detnov DTD-210A addressable heat detector (58 °C fixed and rate of rise) : LED status indicator, output for a remote indicator or BUD-200 buzzer, white; needs a Z-200 base; EN 54-5.
Detnov DTD-215A-I addressable high-temperature heat detector (fixed 78 °C) with built-in isolator : LED status indicator, output for a remote indicator or BUD-200 buzzer, white; needs a Z-200 base; EN 54-5 / EN 54-17.
Detnov MAD-425-I addressable input/output module: 5 inputs + 5 relays, built-in isolator, 24 V DC auxiliary supply, supplied in a mounting box; EN 54-18 / EN 54-17.
Detnov MAD-429-I addressable input/output module: 10 inputs + 10 relays, built-in isolator, 24 V DC auxiliary supply, supplied in a mounting box; EN 54-18 / EN 54-17.
Detnov DTD-210A-I addressable heat detector (58 °C fixed and rate of rise) with built-in isolator : LED status indicator, output for a remote indicator or BUD-200 buzzer, white; needs a Z-200 base; EN 54-5 / EN 54-17.
Detnov MAD-412-I addressable relay module: 2 relays (C/NO/NC, 1 A 30 V DC), built-in isolator, loop powered, DIN rail or BOX-ONE box; EN 54-18 / EN 54-17.
Detnov MAD-451-I addressable red manual call point with built-in isolator: resettable element with a break-glass feel, LED status indicator, key included; indoor use; EN 54-11 and EN 54-17.
Detnov DOD-220A-I addressable optical smoke detector with built-in isolator : LED status indicator, output for a remote indicator or BUD-200 buzzer, white; needs a Z-200 base; EN 54-7 / EN 54-17.
Industrial serial to fibre optic converter: RS-232, RS-485 and RS-422 over multimode fibre up to 5 km, SC connectors, DIN rail or wall mount, -40 … +85 °C.
Detnov MAD-431-I addressable sounder module: 1 supervised 24 V output for sounders and beacons, built-in isolator, 24 V DC auxiliary supply; EN 54-18 / EN 54-17.
Detnov MAD-452-I addressable red manual call point with built-in isolator: LED status indicator, resettable element, supplied with TBD-200 protective cover, surface box and test key; EN 54-11 and EN 54-17.
Detnov MAD-441-I addressable conventional zone module: 1 conventional zone (up to 20 detectors and/or 32 call points per zone), built-in isolator, 24 V DC auxiliary supply; EN 54-18 / EN 54-17.
Detnov MAD-432-I addressable sounder module: 2 supervised 24 V outputs for sounders and beacons, built-in isolator, 24 V DC auxiliary supply; EN 54-18 / EN 54-17.
Detnov MAD-442-I addressable conventional zone module: 2 conventional zones (up to 20 detectors and/or 32 call points per zone), built-in isolator, 24 V DC auxiliary supply; EN 54-18 / EN 54-17.
Rosslare AY-K12C slim 125 kHz EM proximity reader that reads the card serial number (CSN): Wiegand 26, RS-232 or Clock & Data output, read range up to 8 cm, epoxy potted, IP65, indoor and outdoor use.
Takex MX-12FAMD dual-zone PIR and microwave outdoor detector: 180° up to 12 m, left and right sides separately 2–12 m, anti-masking, front and back tamper, IP55.
Takex MX-12FAM dual-zone outdoor PIR: 180° up to 12 m, separately adjustable 2–12 m range for left and right sides, anti-masking, front and back tamper, IP55.